跳到正文
Racks of formed JGQ hairpin air-heating elements with red identification sleeves
JGQ

Racks of formed JGQ hairpin air-heating elements with red identification sleeves

JGQBuilt to drawingJB/T 2379-93

JGQ 型管状电热元件

JGQ 型管状电热元件

用于加热烘箱、烘道、风管和电炉内空气的金属护套管状元件。10 号钢护套,最高介质温度 300 °C,45 mm 紧固件配 M22×1.5 螺母。

Max medium temperature
572 °F(300 °C)
Power range
0.25 – 3 kW
Voltage
36 / 55 / 110 / 220 / 380 V, 50 Hz
Sheath material
10# steel, 304 stainless
Medium
Air
Mounting
Threaded boss, Bracket, Bore insert
Tube diameter
0.63 in
Watt density guidance
≤ 2 W/cm² (13 W/in²) recommended in still air
Lead time
12–20 days
MOQ
20 units
Pricing
On application

Design notes

六种弯管形式,0.25–3.0 kW,36 V 至 380 V

The JGQ series is the workhorse element behind most Chinese-built drying and baking equipment. A nickel-chrome or iron-chrome-aluminum resistance coil runs down the axis of a Ø16 mm steel tube, the annulus is packed with compacted fused magnesium oxide, and both ends are swaged and sealed with silicone. The result conducts heat well, insulates electrically, and survives the vibration and thermal shock of a production line.

Six bend forms cover the usual mounting problems. JGQ1 and JGQ2 are single and double hairpins for shallow plenums. JGQ3 is a triple hairpin where more kilowatts have to fit a fixed width. JGQ4 is a long, narrow U for duct walls. JGQ5 is a deep serpentine for tall ovens. JGQ6 is a compact low-voltage form for 36, 55 and 110 V control circuits and equipment that must run at safety extra-low voltage.

Because air is a poor heat-transfer medium, watt density is the number that matters. Where an oil heater can push past 3 W/cm², an air element in still air should stay near 2 W/cm² or the sheath climbs toward its oxidation limit and the coil fails long before its rated life. Where the design brief needs more kilowatts than the duct area allows, the answer is a finned element rather than a hotter plain tube.

Features

  • Ø16 mm 管径,45 mm 紧固件长度,M22×1.5 紧固螺母
  • 压实的熔融氧化镁填充,绝缘强度高、导热快
  • 硅胶密封端部,储存期间抗潮气侵入
  • 六种标准弯管形式;其他形状均可按图定制
  • 绝缘电阻 ≥ 1 MΩ,耐压 2 kV / 1 分钟

Typical applications

  • 烘烤与固化炉
  • 烘道与输送式干燥机
  • 空调风道再热盘管
  • 电炉与热处理室
  • 粉末喷涂固化线

North American build options

Voltage
120 / 208 / 240 / 277 / 480 / 600 V @ 60 Hz
Threads
NPT or BSP cut to order
Flanges
ANSI B16.5 150# / 300#
Drawings
Issued in inches on request

These are build options, not stock items — the catalog part numbers above are 50 Hz with metric fine threads. State what you need on the RFQ.

Part numbers & dimensions

24 catalog part numbers in the JGQ series

Part numberVoltagePowerA — overallB — heatedC — widthQuote
JGQ1-220/0.5220 V0.5 kW19.3 in13 in
JGQ1-220/0.75220 V0.75 kW27.2 in20.9 in
JGQ2-220/1.0220 V1 kW19.3 in13 in7.87 in
JGQ2-220/1.5220 V1.5 kW27.2 in20.9 in15.7 in
JGQ3-380/2.0380 V2 kW23.2 in16.9 in11.8 in
JGQ3-380/2.5380 V2.5 kW27.2 in20.9 in15.7 in
JGQ3-380/3.0380 V3 kW31.1 in24.8 in19.7 in
JGQ4-220/0.8220 V0.8 kW31.5 in5.04 in2.09 in
JGQ4-220/1.0220 V1 kW39.4 in5.04 in2.09 in
JGQ4-220/1.2220 V1.2 kW47.2 in5.04 in2.09 in
JGQ4-220/1.4220 V1.4 kW55.1 in5.04 in2.09 in
JGQ5-220/0.7220 V0.7 kW33.9 in26 in3.94 in
JGQ5-220/0.8220 V0.8 kW49.6 in33.9 in7.87 in
JGQ5-220/0.9220 V0.9 kW61.4 in37.8 in11.8 in
JGQ5-220/1.1220 V1.1 kW73.2 in45.7 in13.8 in
JGQ5-220/1.2220 V1.2 kW81.1 in49.6 in15.7 in
JGQ5-220/1.3220 V1.3 kW89 in49.6 in19.7 in
JGQ5-220/1.5220 V1.5 kW101 in61.4 in19.7 in
JGQ6-36/0.2536 V0.25 kW10.2 in4.72 in2.76 in
JGQ6-55/0.2555 V0.25 kW10.2 in4.72 in2.76 in
JGQ6-55/0.355 V0.3 kW13.4 in7.87 in2.76 in
JGQ6-110/0.4110 V0.4 kW15.4 in9.84 in2.76 in
JGQ6-110/0.5110 V0.5 kW17.3 in11.8 in2.76 in
JGQ6-220/0.6220 V0.6 kW26 in19.7 in2.76 in

A/B/C are nominal catalog dimensions. The controlling dimensions on any order are those on the drawing approved before production.

Minimum order quantity for this series is 20 units. Dimensions switch between millimetres and inches with the unit toggle in the header.

Full specification

Sheath material
10# steel (304 stainless on request)
Tube diameter
Ø16 mm
Max. medium temperature
300 °C
Voltage range
36 / 55 / 110 / 220 / 380 V, 50 Hz
Power range
0.25 – 3.0 kW
Fastening boss length
45 mm
Fastening nut
M22 × 1.5
Insulation resistance
≥ 1 MΩ at 500 V DC
Dielectric strength
2 kV, 1 minute
Permitted supply tolerance
≤ 1.1 × rated voltage
Ambient humidity
≤ 95 % RH, non-explosive, non-corrosive
Design life
10,000 h typical

Questions engineers ask

What watt density should I use for an air-heating element?

Stay near 2 W/cm² in still air and you can go higher — up to about 3.5 W/cm² — where forced convection sweeps the element continuously. Exceeding that in still air raises sheath temperature past the point where the resistance coil oxidizes, and the element fails well short of its 10,000-hour design life. If the kilowatts will not fit at a safe density, add surface area with a finned element rather than pushing the plain tube harder.

Can a JGQ element be run vertically?

Yes, and for air heating there is no restriction. The rule that matters more is that the whole heated length stays inside the air stream: any part of the heated zone sitting outside the duct, in still or dead air, will run far hotter than the rest and become the failure point. Keep the unheated cold ends outside the duct wall and the heated length entirely inside it.

Why does the catalog quote a 300 °C maximum when the sheath can go hotter?

300 °C is the maximum medium temperature — the temperature of the air around the element — not the sheath temperature. The sheath always runs hotter than the medium. Rating on medium temperature is what lets you size directly from your process set-point without back-calculating sheath rise.

Do you supply non-catalog lengths and bend forms?

Yes. The six catalog forms cover common oven and duct layouts, but roughly half of what leaves the plant is made to a customer drawing. Send a dimensioned sketch with the kilowatts, voltage, medium and mounting detail and we will quote the formed element against it.

Watt-density figures and temperature limits on this page are design guidance, not warranties. The safe value for your installation depends on the medium, its flow and how the element is mounted — which is why we ask for the duty rather than only the part number.